Power Distribution
Hi-Amp Circuit Breaker 120A Sm Surface Mount - 420878-1 - 354-4208781F1
Hi-Amp Circuit Breaker 120A Pm Panel Mount - 420888-1 - 354-4208881F1
Hi-Amp Circuit Breaker 100A Sm Surface Mount - 420877-1 - 354-4208771F1
Hi-Amp Circuit Breaker 100A Pm Panel Mount - 420887-1 - 354-4208871F1
Header For Fuse Display - Header Sign W/Hardware - 50-Headerfusef1
Guest 22208A Rectangle Control Panel For Stainless Steel Spots - 22208A - 85-22208Af1
Use with 22040A, 22041A, 22044, OR 22045.
Generation Ii Mpc Panel W/Finger Release Remote Control - 8M0011214 - 710-8M0011214F1
Comes with 4 ft. trim and trailer switch harness with the 4 pin Molex connector. All installations require a separate ignition switch and throttle/shift cables to complete the installation. Neutral safety switch leads are 6-1/2 ft. long and have bullet connectors on the ends. Lanyard stop switch leads also have bullet connectors on ends. Must use Gen II throttle/shift cable design. (883719A__ or 897978A__) The power trim extension harness also needs to be ordered separately: (84-817659A 1 and 84-881125A 1= 4 pin Molex to traditional Mercury 3 blade P/T connector). (84-865772A01 and 84-865772A02 = 4 pin Molex to the Packard 3 pin P/T connector).
Garmin 0101300907 Ondeck™ Remote Monitoring/Connectivity Relay Switch (24V) - 010-13009-07 - 322-0101300907F1
24V Relay Switch for the OnDeck™ system.Track, monitor and control up to 5 switches on your boat with the OnDeck™ system, a fully integrated remote connectivity solution. Get updates on your boat's battery status, bilge activity, shore power, temperature changes and more. Set up alarm notifications in the ActiveCaptain® app An active subscription plan is required. Choose between an annual plan or pay month-to-month.
Garmin 0101300901 Ondeck™ Remote Monitoring/Connectivity Relay Switch (12V) - 010-13009-01 - 322-0101300901F1
12V Relay Switch for the OnDeck™ system.Track, monitor and control up to 5 switches on your boat with the OnDeck™ system, a fully integrated remote connectivity solution. Get updates on your boat's battery status, bilge activity, shore power, temperature changes and more. Set up alarm notifications in the ActiveCaptain® app An active subscription plan is required. Choose between an annual plan or pay month-to-month.
Fusion Sound Panel Mounting Spacer, White 41 Mm - 010-12586-00 - 830-0101258600F1
The Sound-Panel has three accessory mounting spacers available for the RV-FS402W/ RV-FS402B sound panel to create a professional indoor or outdoor install, where cavity depth prevents standard speaker installation. Select the spacer size that suits your installation mounting depth. 41 mm Spacer: Use in a surface mount installation
Fuse Plug In 4 Amp 5/Cd Ato - Fs79510 - 11-Fs79510F1
5 Pack, ATO Blade Style.
Fuse Mega 300A 32V - 5108-Bss - 661-5108F1
Most economical fuse for 100 to 300 Amp circuit protection. Interrupt capacity 2000 Amps DC and maximum voltage is 32 DC.
Fuse Mega 250 Amp/32 Volt - 5107-Bss - 661-5107F1
Most economical fuse for 100 to 300 Amp circuit protection. Interrupt capacity 2000 Amps DC and maximum voltage is 32 DC.
Fuse Mega 200 Amp/32 Volt - 5105-Bss - 661-5105F1
Most economical fuse for 100 to 300 Amp circuit protection. Interrupt capacity 2000 Amps DC and maximum voltage is 32 DC.
Fuse Mega 175 Amp/32 Volt - 5104-Bss - 661-5104F1
Most economical fuse for 100 to 300 Amp circuit protection. Interrupt capacity 2000 Amps DC and maximum voltage is 32 DC.
Fuse Mega 150 Amp/32 Volt - 5103-Bss - 661-5103F1
Most economical fuse for 100 to 300 Amp circuit protection. Interrupt capacity 2000 Amps DC and maximum voltage is 32 DC.
Fuse Mega 125 Amp/32 Volt - 5102-Bss - 661-5102F1
Most economical fuse for 100 to 300 Amp circuit protection. Interrupt capacity 2000 Amps DC and maximum voltage is 32 DC.
Fuse Mega 100 Amp/32 Volt - 5101-Bss - 661-5101F1
Most economical fuse for 100 to 300 Amp circuit protection. Interrupt capacity 2000 Amps DC and maximum voltage is 32 DC.
Fuse Maxi 80 Ampere - 5143-Bss - 661-5143F1
Tin-plated connector blades for corrosion resistance and visible indication of blown condition. Interrupt capacity is 1000 amps DC and 32 Volts DC maximum.
Fuse Maxi 70 Ampere - 5142-Bss - 661-5142F1
Tin-plated connector blades for corrosion resistance and visible indication of blown condition. Interrupt capacity is 1000 amps DC and 32 Volts DC maximum.
Fuse Maxi 60 Ampere - 5141-Bss - 661-5141F1
Tin-plated connector blades for corrosion resistance and visible indication of blown condition. Interrupt capacity is 1000 amps DC and 32 Volts DC maximum.
Fuse Maxi 50 Ampere - 5140-Bss - 661-5140F1
Tin-plated connector blades for corrosion resistance and visible indication of blown condition. Interrupt capacity is 1000 amps DC and 32 Volts DC maximum.
Fuse Maxi 40 Ampere - 5139-Bss - 661-5139F1
Tin-plated connector blades for corrosion resistance and visible indication of blown condition. Interrupt capacity is 1000 amps DC and 32 Volts DC maximum.
Fuse Maxi 30 Ampere - 5138-Bss - 661-5138F1
Tin-plated connector blades for corrosion resistance and visible indication of blown condition. Interrupt capacity is 1000 amps DC and 32 Volts DC maximum.
Fuse Jjn (Class T) 400 Amp - 5121-Bss - 661-5121F1
Fast short circuit response makes this the best choice to protect high amperage electronics equipment such as inverters. 20,000 Amp Interupt Capacity (AIC) UL rated for DC applications under UL189L.
Fuse Jjn (Class T) 350 Amp - 5120-Bss - 661-5120F1
Fast short circuit response makes this the best choice to protect high amperage electronics equipment such as inverters. 20,000 Amp Interupt Capacity (AIC) UL rated for DC applications under UL189L.
Fuse Jjn (Class T) 300 Amp - 5119-Bss - 661-5119F1
Fast short circuit response makes this the best choice to protect high amperage electronics equipment such as inverters. 20,000 Amp Interupt Capacity (AIC) UL rated for DC applications under UL189L.
Fuse Jjn (Class T) 250 Amp - 5118-Bss - 661-5118F1
Fast short circuit response makes this the best choice to protect high amperage electronics equipment such as inverters. 20,000 Amp Interupt Capacity (AIC) UL rated for DC applications under UL189L.
Fuse Jjn (Class T) 225 Amp - 5117-Bss - 661-5117F1
Fast short circuit response makes this the best choice to protect high amperage electronics equipment such as inverters. 20,000 Amp Interupt Capacity (AIC) UL rated for DC applications under UL189L.
Fuse Holder Inline Weatherproof - Fs35870 - 11-Fs35870F1
Designed to accept automative style spade-terminal fuses. ATO/ATC. Bulk packed
Fuse Holder Agc/Mdl Waterproof 30A - 5061-Bss - 661-5061F1
Fuse Holder - Fs69130 - 11-Fs69130F1
Designed to accept automative style spade-terminal fuses. ATO/ATC. Bulk packed
Fuse Holder - 420502-1 - 354-4205021F1
AGC Fuse Holder with Screw-On Cap is constructed of molded Bakelite with stamped brass contacts and a screw-on cap. Panel mounted to provide overcurrent protection in electrical circuits. For use with standard AGC 1/4" x 1-1/4" glass style fuses. Maximum 15A @ 12VDC. Solder terminal. Fuse not included.
Fuse Holder - 420501-1 - 354-4205011F1
Push in cap is made of stamped brass and molded bakelite.
Fuse Holder - 12661 - 50-12661F1
Accommodates a variety of sizes. Fuse not included.
Fuse Block Term.10 Gang Carded - M-449-Bp - 12-M449Bpf1
Solid brass busbar safely carries up to 150A. Two 1/4" -20 diameter brass stud with hex nuts. 8-32 round head screws for attaching wires. Moisture repellent thermoplastic insulator base. 2 mounting holes. Safely carries up to 150 amps.
Fuse Block Anl 250 Amp - 5005-Bss - 661-5005F1
Accepts wide range of ANL Fuse amperages for a versatile ignition protected fusing system. Tin-plated copper bus and stainless steel hardware. A 5/16" (M8) stud terminals. Insulation cover with breakouts allow cable access from all directions. Maximum rating: 32 Volts DC.
Fuse Block Agc 6 Cir. - 5018-Bss - 661-5018F1
Clear insulating cover with label recesses for standard Blue Sea System labels. Cover insulates all conductive parts, satisfying ABYC/USCG requirements and stores spare fuses. Nickel-plated metal components and copper contact clips. Rated for 32V max, 100 amps max per block, 30 amps max per circuit. Uses AGC, MDL and all other 3AG glass fuses.
Fuse Block Agc 6 Cir W/Groun - 5015-Bss - 661-5015F1
Clear insulating cover with label recesses for standard Blue Sea System labels. Cover insulates all conductive parts, satisfying ABYC/USCG requirements and stores spare fuses. Nickel-plated metal components and copper contact clips. Rated for 32V max, 100 amps max per block, 30 amps max per circuit. Uses AGC, MDL and all other 3AG glass fuses.
Fuse Block 4 Gang - Fs40550-1 - 11-Fs405501F1
Use with SFE, AGC, or MDL fuses up to 20 AmpCommon bus bar connects hot side of fuses for power feedSeparate bus bar for ground or unfused common hot feedBrass fuse clips, 8-32 stud terminals
Fuse Assy-90 Amp Ss<88-79023A91 - 8M0207795 - 710-88-8M0207795F1
Fuse Assy 55 Amp Ss< 79023A56 - 79023T56 - 710-88-79023T56F1
Fuse Anl 80 Amp - 5124-Bss - 661-5124F1
Tin-plated connector blades for corrosion resistance. Visible indication of blown condition. Interrupt capacity is 6000 Amps DC and 32 volts DC maximum. Ignition protected- safe for installation aboard gasoline powered boats.
Fuse Anl 750 Amp - 5163-Bss - 661-5163F1
Tin-plated connector blades for corrosion resistance. Visible indication of blown condition. Interrupt capacity is 6000 Amps DC and 32 volts DC maximum. Ignition protected- safe for installation aboard gasoline powered boats.
Fuse Anl 600 Amp - 5161-Bss - 661-5161F1
Tin-plated connector blades for corrosion resistance. Visible indication of blown condition. Interrupt capacity is 6000 Amps DC and 32 volts DC maximum. Ignition protected- safe for installation aboard gasoline powered boats.
Fuse Anl 60 Amp - 5123-Bss - 661-5123F1
Tin-plated connector blades for corrosion resistance. Visible indication of blown condition. Interrupt capacity is 6000 Amps DC and 32 volts DC maximum. Ignition protected- safe for installation aboard gasoline powered boats.
Fuse Anl 500 Amp - 5137-Bss - 661-5137F1
Tin-plated connector blades for corrosion resistance. Visible indication of blown condition. Interrupt capacity is 6000 Amps DC and 32 volts DC maximum. Ignition protected- safe for installation aboard gasoline powered boats.
Fuse Anl 50 Amp - 5122-Bss - 661-5122F1
Tin-plated connector blades for corrosion resistance. Visible indication of blown condition. Interrupt capacity is 6000 Amps DC and 32 volts DC maximum. Ignition protected- safe for installation aboard gasoline powered boats.
Fuse Anl 400 Amp - 5136-Bss - 661-5136F1
Tin-plated connector blades for corrosion resistance. Visible indication of blown condition. Interrupt capacity is 6000 Amps DC and 32 volts DC maximum. Ignition protected- safe for installation aboard gasoline powered boats.
Fuse Anl 40 Amp - 5165-Bss - 661-5165F1
Tin-plated connector blades for corrosion resistance. Visible indication of blown condition. Interrupt capacity is 6000 Amps DC and 32 volts DC maximum. Ignition protected- safe for installation aboard gasoline powered boats.
Fuse Anl 350 Amp - 5135-Bss - 661-5135F1
Tin-plated connector blades for corrosion resistance. Visible indication of blown condition. Interrupt capacity is 6000 Amps DC and 32 volts DC maximum. Ignition protected- safe for installation aboard gasoline powered boats.
Fuse Anl 35 Amp - 5164-Bss - 661-5164F1
Tin-plated connector blades for corrosion resistance. Visible indication of blown condition. Interrupt capacity is 6000 Amps DC and 32 volts DC maximum. Ignition protected- safe for installation aboard gasoline powered boats.
Fuse Anl 300 Amp - 5133-Bss - 661-5133F1
Tin-plated connector blades for corrosion resistance. Visible indication of blown condition. Interrupt capacity is 6000 Amps DC and 32 volts DC maximum. Ignition protected- safe for installation aboard gasoline powered boats.
Fuse Anl 250 Amp - 5131-Bss - 661-5131F1
Tin-plated connector blades for corrosion resistance. Visible indication of blown condition. Interrupt capacity is 6000 Amps DC and 32 volts DC maximum. Ignition protected- safe for installation aboard gasoline powered boats.
Fuse Anl 200 Amp - 5129-Bss - 661-5129F1
Tin-plated connector blades for corrosion resistance. Visible indication of blown condition. Interrupt capacity is 6000 Amps DC and 32 volts DC maximum. Ignition protected- safe for installation aboard gasoline powered boats.
Fuse Anl 175 Amp - 5128-Bss - 661-5128F1
Tin-plated connector blades for corrosion resistance. Visible indication of blown condition. Interrupt capacity is 6000 Amps DC and 32 volts DC maximum. Ignition protected- safe for installation aboard gasoline powered boats.
Fuse Anl 150 Amp - 5127-Bss - 661-5127F1
Tin-plated connector blades for corrosion resistance. Visible indication of blown condition. Interrupt capacity is 6000 Amps DC and 32 volts DC maximum. Ignition protected- safe for installation aboard gasoline powered boats.
Fuse Anl 130 Amp - 5126-Bss - 661-5126F1
Tin-plated connector blades for corrosion resistance. Visible indication of blown condition. Interrupt capacity is 6000 Amps DC and 32 volts DC maximum. Ignition protected- safe for installation aboard gasoline powered boats.
Fuse Anl 100 Amp - 5125-Bss - 661-5125F1
Tin-plated connector blades for corrosion resistance. Visible indication of blown condition. Interrupt capacity is 6000 Amps DC and 32 volts DC maximum. Ignition protected- safe for installation aboard gasoline powered boats.
Fuse Agc 10 Amp Slow Blow Glass Tube - 5230-Bss - 661-5230F1
Fuse A3T (Class T) 200 Amp - 5116-Bss - 661-5116F1
Fast short circuit response makes this the best choice to protect high amperage electronics equipment such as inverters. 20,000 Amp Interupt Capacity (AIC) UL rated for DC applications under UL189L.
Fuse A3T (Class T) 175 Amp - 5115-Bss - 661-5115F1
Fast short circuit response makes this the best choice to protect high amperage electronics equipment such as inverters. 20,000 Amp Interupt Capacity (AIC) UL rated for DC applications under UL189L.
Fuse A3T (Class T) 150 Amp - 5114-Bss - 661-5114F1
Fast short circuit response makes this the best choice to protect high amperage electronics equipment such as inverters. 20,000 Amp Interupt Capacity (AIC) UL rated for DC applications under UL189L.
Fuse A3T (Class T) 125 Amp - 5113-Bss - 661-5113F1
Fast short circuit response makes this the best choice to protect high amperage electronics equipment such as inverters. 20,000 Amp Interupt Capacity (AIC) UL rated for DC applications under UL189L.
Fuse A3T (Class T) 110 Amp - 5112-Bss - 661-5112F1
Fast short circuit response makes this the best choice to protect high amperage electronics equipment such as inverters. 20,000 Amp Interupt Capacity (AIC) UL rated for DC applications under UL189L.
Fuse & Junction Block 8 Gang - Fs40570-1 - 11-Fs405701F1
Use with SFE, AGC, or MDL fuses up to 20 AmpCommon bus bar connects hot side of fuses for power feedSeparate bus bar for ground or unfused common hot feedBrass fuse clips, 8-32 stud terminals
Front Mount Socket Panel Trp Triple Hole - 426023-1 - 354-4260231F1
Front Mount Socket Panel Sgl Single Hole - 426021-1 - 354-4260211F1
Front Mount Socket Panel Dbl Double Hole - 426022-1 - 354-4260221F1
Fireboy-Xintex G1Bbr Gasoline Fume Detector, Single Channel W/1 Sensor & 10A Relay To Start Blower - G-1Bb-R - 669-G1Bbrf1
Gasoline fumes in a bilge or engine compartment, with or without a blower fan, have the potential to be a serious risk at any time. First, because fuel leaks create new fumes as rapidly as the blower clears old fumes away. With the fan off, the hazard is increased. Second, the blower fan is typically operating prior to engine start up, thus offering no protection from the ignition of fumes by electrical short circuit, smoking or their causes. Xintex offers a full line of gas detectors and accessories to match your specific needs.
Fireboy Es500001 Engine Shutdown 5 Circuit - Es500001 - 669-Es500001F1
Required for Diesel Engines. Compressed gas suppressants will not stall a diesel engine. If fire breaks out aboard a diesel powered vessel, the engine must be shut down immediately. Continued operation may remove the agent creating the possibility of re-ignition. FIREBOY engine shutdown systems respond automatically when a Fireboy system discharges. Includes a round helm display unit with an integrated alarm horn, charged/discharged lights and an override switch for restart or control of auto-shutdown. 12/24 VDC.
Fireboy Es300001 Engine Shutdown 3 Circuit - Es300001 - 669-Es300001F1
Required for Diesel Engines. Compressed gas suppressants will not stall a diesel engine. If fire breaks out aboard a diesel powered vessel, the engine must be shut down immediately. Continued operation may remove the agent creating the possibility of re-ignition. FIREBOY engine shutdown systems respond automatically when a Fireboy system discharges. Includes a round helm display unit with an integrated alarm horn, charged/discharged lights and an override switch for restart or control of auto-shutdown. 12/24 VDC.
